LOCATION

MGK Kemayoran LT.GF Blok C.1 No.5

Lutron CO2-9904SD

  • 4 channels vibration recorder, use SD card to save the data along with time information, paperless.
  • Real time data logger, save the measuring data along the time information (year,Model : CO2-9904SD
    • Real time recorder, save the data into the SD memory card and can be downloaded to the Excel,  extra software is no need.
    • Measurement : CO2 (Carbon dioxide), Humidity, Dew point, temperature.
    • CO2 range : 0 to 6,000 ppm x 1 ppm.
    • Humidity range: 10 to 95 %RH.
    • Dew point : -25.3 to 48.9 oC, oC/oF.
    • Temp. range : 0 to 50.0 oC, oC/oF.
    • CO2 sensor : NDIR, long term reliability.
    • Humidity sensor : Precision capacitance sensor.
    • Alarm setting with the beeper sound output.
    • Sampling time for data recorder is 2 seconds to 8 hours.
    • 2 probes : CO2 and Humidity probe.
    • Hard carrying case is included
    • Can use 2 GB to 16 GB SD card (optional).
    • RS232/USB computer interface.
    • Patented.

    month, date,  hour, minute, second) into the SD memory card and can be downloaded to the Excel, extra  software is no need.

  • Show CH1 to CH4 vibration values in the same LCD.
  • Time information : Year, Month, Date, Hour, Minute and Second.
  • Sampling setting : 1 to 3600 seconds.
  • Function : Acceleration/Velocity/Displacement.
  • Acceleration : 200 m/s2.
  • Velocity : 200 mm/s.
  • Displacement (p-p) : 2 mm.
  • Max hold, peak value, data hold, Max./Min..
  • RS232/USB computer interface.
  • Memory card size : 1 GB to 16 GB.
  • Supper large LCD with backlight, easy reading.
  • Data hold, Record (Max., Min.).
  • RS232/USB computer interface.
  • Include 1 PC sensor vibration set, VB-83.
  • Extra vibration sensor set, VB-83 can be ordered. When changing the VB-83, it is not necessary to  make the new calibration again.
  • Optional Tip type vibration sensor set, VB-84.
  • DC 1.5V (UM-3/AA) x 8 PCs or DC 9V adapter in.
  • Patented.

Deskripsi

SD Card real time recorder, 6000 ppm
CO2 METER, + Humidity/Temp.
Model : CO2-9904SD

  • Real time recorder, save the data into the SD memory card and can be downloaded to the Excel,  extra software is no need.
  • Measurement : CO2 (Carbon dioxide), Humidity, Dew point, temperature.
  • CO2 range : 0 to 6,000 ppm x 1 ppm.
  • Humidity range: 10 to 95 %RH.
  • Dew point : -25.3 to 48.9 oC, oC/oF.
  • Temp. range : 0 to 50.0 oC, oC/oF.
  • CO2 sensor : NDIR, long term reliability.
  • Humidity sensor : Precision capacitance sensor.
  • Alarm setting with the beeper sound output.
  • Sampling time for data recorder is 2 seconds to 8 hours.
  • 2 probes : CO2 and Humidity probe.
  • Hard carrying case is included
  • Can use 2 GB to 16 GB SD card (optional).
  • RS232/USB computer interface.
  • Patented.