Jual Spectrophotometer Evolution™ 350 Thermo Scientific

Description

Evolution™ 350 UV-Vis Spectrophotometer, Cat. No. 840-310800
Designed for laboratories requiring higher performance, the Thermo Scientific™ Evolution™ 350 UV-Vis Spectrophotometer’s double beam optical design delivers precision and outstanding reliability for advanced applications. From sample to final report, intuitive software quickly guides you through each step of your analysis. Comprehensive tools for data collection, processing and reporting deliver the results you need for quantitative analysis, scanning and kinetics applications. Expansive accessory choices offer flexibility to analyze almost any sample type.

Specification :

Product Size
Baseline Flatness±0.0015 A (200–800 nm)
2.0 nm SBW, smoothed
DescriptionEvolution 350 Spectrophotometer
Detector TypeDual Matched Silicon Photodiodes
Dimensions (L x W x H)53 x 61 x 38 cm / 20.8 x 24 x 14.9 in.
Drift<0.0005 Abs/hour, 500 nm, 2.0 nm SBW, 2 hr warm-up
Electrical Requirements100–240 V, 50–60 Hz
For Use With (Application)Academic, Chemicals, Food & Beverage, Chemicals Environmental, Industrial QA/QC, Material Science, Pharmaceuticals
LampXenon Flash Lamp
Typical Lifetime: >5 years. Longer if not using live signal

Warranty Period: 3 year source replacement warranty

NoisePhotometric

0A: <0.00018 A

1A: <0.00022 A

2A: <0.00050 A

500 nm, 2.0 nm SBW, RMS

Optical DesignModified Ebert; Double beam with sample and reference cuvette/accessory positions
Pharmacopoeia Compliance TestingResolution (Toluene in Hexane) Peak/Trough Ratio >1.8 with 1nm slit setting

Photometric Accuracy (60mg/L K2Cr2O7) <±0.01 A relative to calibrated sealed standard

Stray Light <0.13 %T at 198 nm with KCl per EP

220 nm: <0.01%T NaI (behaves identically to KI for USP)

Wavelength Accuracy ±0.20 nm (546.11 nm Hg emission line), ±0.30 nm 190–900 nm

Wavelength Repeatability Peak separation of repetitive scanning of Hg line source <0.10 nm

Photometric Accuracy Instrument1A: ±0.004 A

2A: ±0.004 A

3A: ±0.006 A

 

Measured at 546 nm using neutral density filters traceable to NIST. When testing instrument performance, the specification used for pass/fail determination is the sum of the instrument specification listed here and the uncertainty in the calibration data for the filter, listed on the calibration certificate.

Photometric Display±6 A
Photometric Range>4 A
Photometric ReadoutAbsorbance, % Transmission, % Reflectance, Kubelka-Munk, Log (1/R), Log(ABS), ABS x Factor, Intensity
Photometric Repeatability1A: ±0.0025 A
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Concentration, 1st–4th Derivative
Spectral BandwidthVariable 0.5, 1.0, 1.5, 2.0, 4.0 nm
Stray Light198 nm: 2.9 A KCl

220 nm: 4.2 A NaI

340 nm: 4.3 A NaNO2

Wavelength Accuracy±0.20 nm (546.11 nm Hg emission line), ±0.30 nm 190–900 nm
Wavelength Data Interval10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05 nm
Wavelength Range190–1100 nm
Wavelength RepeatabilityStandard deviation of 10 measurements <0.05 nm
Wavelength Scan Speed3800, 2400, 1200, 600, 240, 120, 60, 30, 10, 5, 1 nm/min

Intelliscan

Weight (English)48.5 lbs
Weight (Metric)22 kg

 