LOCATION

MGK Kemayoran LT.GF Blok C.1 No.5

WOHLER A 550 A 500 L FLUE GAS ANALYZER

Portable Flue Gas Emissions Analyzer with Capitalize Superior and Accuracy

As tough as cast iron, but as easy to operate as a smartphone – that‘s what Wohler‘s new Flue Gas Emssions Analyzer feels like in your hand. A tap of your finger on the Wohler A 550 INDUSTRIAL is all that is required to perform a complete analysis and inspection of boilers and burners. The Flue Gas Emissions Analyzer is designed to be used in tough industrial heat processes. The in-stack stainless steel sinter-filter probe protects the analyzer against heavy dust loads.

 

Deskripsi

WOHLER A 550 /A 500 L FLUE GAS ANALYZER

PORTABLE FLUE GAS ANALYZER WITH SUPERIOR ACCURACY

No matter how you look at it, the new Wöhler A 550 INDUSTRIAL really is a „nifty piece of equipment“: The individual functions can be launched as intuitively as using a smartphone via the large 7″ color touchscreen. And the brightly lit monitor can be read anywhere. The large screen, the clear arrangement and the graphical presentation of readings allow excellent readability.

Oxygen concentration (O2 ) in flue gas
DisplayVolume % referenced to dry flue gas
Measurement principleElectrochemical sensor
Range0.0-21.0 vol. %
Accuracy± 0.3 Vol.-%
Carbon monoxide (CO 4,000 ppm) in flue gas (Wohler A 550)
DisplayVolume ppm referenced to dry flue gas
Measurement principleElectrochemical sensor
Range0-4,000 vol. ppm; resolution 1 vol. ppm
Accuracy±20 ppm (< 400 ppm), otherwise 5% of reading
Carbon monoxide (CO) in flue gas (Wohler A 550 L)
DisplayVolume ppm referenced to dry flue gas
Measurement principleElectrochemical sensor
Range0-35,000 vol. ppm; resolution 1 vol. ppm
Accuracy± 100 ppm (< 1,000 ppm), otherwise 10% of reading (with H2 < 5% of reading)
Carbon monoxide (COhigh) in flue gas (optional)
DisplayVolume ppm referenced to dry flue gas
Measurement principleElectrochemical sensor
Range0-100,000 vol. ppm; resolution 1 vol. ppm
Accuracy± 100 ppm (< 1,000 ppm), otherwise 10% of reading (with H2 < 5 % of reading)
Nitric oxide concentration (NO) in flue gas (optional)
DisplayVolume ppm referenced to dry flue gas
Measurement principleElectrochemical Sensor
Range0-3,000 vol. ppm (continuously up to 1,000);
Resolution1 vol. ppm
Accuracy±5 Vol.-ppm (<100 ppm), otherwise 5 % of reading
Nitrogen dioxide concentration (NO2 ) in flue gas (optional)
DisplayVolume ppm referenced to dry flue gas
Measurement principleElectrochemical sensor
Range0-1000 vol. ppm (continuously up to 200); resolution 1 vol. ppm
Accuracy±5 vol. ppm (< 100 ppm), otherwise 5 % of reading
Sulfur dioxide (SO2 ) in flue gas (optional)
DisplayVolume ppm referenced to dry flue gas
Measurement principleElectrochemical sensor
Range0-5,000 vol. ppm; resolution 1 vol. ppm
Accuracy± 10 vol. ppm (0…200 ppm), otherwise 5 % of reading
Chimney draft / differential pressure (PD) with 4 Pa test (Wohler A 550)
DisplayinWC
Measurement principleSemi-conductor diaphragm
Range0.00 to ± 44.16 inWC; resolution 0.004 inWC (< 4.01 inWC), otherwise 0.004 inWC, with ventilation loss measurement 0.004 inWC
Accuracy0.0012 inWC (< 0.04 inWC), otherwise 3 % of reading Drift < 0.00081 inWC in 5 minutes
Chimney draft / differential pressure (PD) (Wohler A 550 L)
DisplayinWC
Measurement principleSemi-conductor diaphragm
Range0.00 to ± 44.16 inWC; resolution 0.004 inWC
Accuracy0.008 inWC (< 0.16 inWC), otherwise 5 % of reading
Flue gas temperature (TS)
Display°F
Measurement principleThermocouple (NiCr-Ni) (NiCr-Ni)
Range-4 °F to 1,472 °F; resolution 32.18 °F
Accuracy32-271.4 °F: ± 35.6°F 271.4-1,472 °F: ± 1.5 % of reading
Combustion air temperature (TA)
Display°F
Measurement principleThermocouple (NiCr-Ni)
Range-4 °F to 212 °F; resolution 32.2 °F
Accuracy±33.8°F
Wood moisture
DisplayMass of water referenced to dry fuel mass
Measurement principleElectrical resistance measurement
Range10.0-40.0%; resolution 0.1%
Accuracy±40% of reading tested to VDI 4206 Part 4
Power supplyLithium-Ion, rechargeable battery 3.7 V, 5800 mAh charges via USB
Battery operating timeApprox. 12 h (depends on operating status and display illumination)
Storage temperature-4 °F to +122 °F
Operating temperature+41-104 °F to maintain stated accuracy
Weight2.75 lbs
Dimensions8.7″ x 6.3″ x 2.2″ (without probe)
Length of cable-hose:67