Specifications Sanwa DCM600DR Clamp Meter

Function Measuring range Best accuracy Resolution Input impedance
DCA 60/600A ±(2%+5) 0.01A
ACA 60/600A ±(2%+5) 0.01A
DCV 600V ±(1%+2) 0.1V 1MΩ
ACV 600V ±(1.2%+5) 0.1V
Resistance 999.9Ω ±(1%+7) 0.1Ω
Continuity Buzzer sounds at less than 40Ω Open voltage: approx. 2.9V
Sampling rate 3 times/sec.
Bandwidth 50-500Hz
Display 6000
Clamp diameter/Conductor size Φ30mm/10×50mm
Battery LR03×2
Battery life Approx. 40 hrs. (Backlight off)
Size/Mass H208×W69×D38mm/Approx. 260g
Safety standards IEC61010 CAT.Ⅲ600V

In the peak hold mode, the measuring range is fixed at 600A.

Optional Accessories:

  • Clip adapter : CL-13a, CL-14,CL-15a, CL-DG3a, TL-9IC
  • Test lead : TL-21M, TLF-120

 

Deskripsi

Sanwa DCM600DR Clamp Meter

Karya Mandiri Techindo has a wide range of Sanwa products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

This DCM600DR can measure a maximum of 600 Amperes of AC/DC current. It can measure AC/DC current up to 600 Volts, the resistance of 999.9Ω, and perform continuity tests with a buzzer alarm. This device is suitable for current and voltage measurements of low-voltage circuitry, electric equipment, and power supply facilities.

The device offers various functions such as data hold, peak hold, zero, etc. It features a 6000-count display with a back-light feature. The device also has an auto-power save feature that turns the screen off after 30 minutes of no use.

Features Sanwa DCM600DR Clamp Meter

  • AC / DC current measurable max. 600A
  • True RMS
  • Peak hold
    When the peak button is pressed, the measuring range will be fixed to the 600A range.
  • Relative value measurement
  • Data hold, Auto power save
  • LCD with back light
    Sampling rate : 3 times / sec. for numeral display,