LOCATION

MGK Kemayoran LT.GF Blok C.1 No.5

Jual Safety Almunized Apparel Blue Eagle AL5

Product Name: Aluminized gaiters
Standards: EN 11612
Size : Height: 9″ , Width: 12″

Deskripsi

  • Limited flame spread (ISO 15025)
    When tested in accordance with ISO 15025 procedure A, the superb aluminized fabric passes the highest requirement (A1) of limited flame spread.
  • Convective heat (ISO 9151)
    When tested in accordance with ISO 9151, the superb aluminized fabric shows an excellent result (B2) in the convective heat performance test. The result shows that the RHTI 24 value = 13.5 s
  • Radiant heat (EN ISO 6942)
    When tested in accordance with ISO 6942 method B at a heat flux density of 20 kW/m², the superb aluminized fabric exceeds the highest class (C4) requirement in the radiant heat performance test. The result shows that the RHTI 24 = 103.2 s
  • Molten aluminum splash (ISO 9185)
    When tested in accordance with ISO 9185, the superb aluminized fabric exceeds the highest class (D3) requirement in the molten aluminum splash performance test. The result shows that the weight of molten aluminum splash is greater than 350 g, while the skin simulant is still undamaged.
  • Molten iron splash (ISO 9185)
    When tested in accordance with ISO 9185, the superb aluminized fabric exceeds the highest class (E3) requirement in the molten iron splash performance test. The result shows that the weight of molten iron splash is greater than 200 g, while the skin simulant is still undamaged.
  • Contact heat (ISO 12127)
    When tested in accordance with ISO 12127 at a temperature of 250℃, the superb aluminized fabric shows an excellent result (F2) in the contact heat performance test. The result shows that the threshold time = 14.8 s
  • Made in Taiwan

 

———————  Features  ———————————————————-

Requirements for EN ISO 11612 Convective heat test
Performance
Levels
Range of HTI 24 values (s)
min. max.
B1 4 < 10.0
B2 10.0 < 20.0
B3 20.0

 

Requirements for EN ISO 11612 Radiant heat test
Performance
Levels
Heat transfer factor RHTI 24 (s)
min. max.
C1 7.0 < 20.0
C2 20.0 < 50.0
C3 50.0 < 95.0
C4 95.0

 

Requirements for EN ISO 11612 Molten aluminium splash
Performance
Levels
Molten aluminium splash (g)
min. max.
D1 100 < 200
D2 200 < 350
D3 350

 

Requirements for EN ISO 11612 Molten iron splash
Performance
Levels
Molten iron splash (g)
min. max.
E1 60 < 120
E2 120 < 200
E3 200

 

Requirements for EN ISO 11612 Contact heat
Performance
Levels
Threshold time (s)
min. max.
F1 5.0 < 10.0
F2 10.0 < 15.0
F3 15.0

Additional information

Item No. AL5
Product Name Aluminized gaiters
Standards EN 11612
Size Height: 9″
Width: 12″
Heat and Fire Protection Approved by European standard EN 11612
Limited flame spread: A1
Convective heat: B2
Radiant heat: C4
Molten aluminum splash: D3
Molten iron splash: E3
Contact heat: F2