Jual Gas Meter/Gas Purging TG-Series (Wet-Test) Ritter

Description

Drum-type Gas Meters TG-Series (Wet-Test)

User Benefits :
Highest accuracy (±0,5%)
Measurement of all gases and gas mixtures with equal accuracy
Use with extremely corrosive and inert gases
Calibration traceable to German National Primary Standard
Lowest measurable flow rates
Largest selection of measuring ranges
Real time data acquisition option for PC (requires option »Pulse Generator«)
Most durable construction – available, both chemically (from high-quality thermoplastics) and mechanically (stainless steel)
Maintenance-free (just checking of packing liquid level required)

8-digit Totalizing Roller Counter
Large, One-needle Dial
Level and Levelling Feet
Magnetic Coupling between the measuring drum and counting mechanism (> no leakage of packing liquid)
Multi-Chamber Measuring Drum
Supports for Thermometer and Manometer
Viton sealing

Performance Specifications :
– Type TG 0.5, Flow Rate Minimum [ltr/h] : 1; Flow Rate Maximum [ltr/h] : 60; Flow Rate Standard [ltr/h]* : 50; Readout Indication Minimum [ltr]** : 0.002; Readout Indication Maximum [ltr] : 9,999,999.9; Measuring Drum Volume [ltr] : 0.5; Pressure Loss Minimum [mbar] : 0.4
– Type TG 1, Flow Rate Minimum [ltr/h] : 2; Flow Rate Maximum [ltr/h] : 120; Flow Rate Standard [ltr/h]* : 100; Readout Indication Minimum [ltr]** : 0.01; Readout Indication Maximum [ltr] : 99,999,999; Measuring Drum Volume [ltr] : 1.0; Pressure Loss Minimum [mbar] : 0.2
– Type TG 3, Flow Rate Minimum [ltr/h] : 6; Flow Rate Maximum [ltr/h] : 360; Flow Rate Standard [ltr/h]* : 300; Readout Indication Minimum [ltr]** : 0.02; Readout Indication Maximum [ltr] : 99,999,999; Measuring Drum Volume [ltr] : 3.0; Pressure Loss Minimum [mbar] : 0.2
– Type TG 5, Flow Rate Minimum [ltr/h] : 10; Flow Rate Maximum [ltr/h] : 600; Flow Rate Standard [ltr/h]* : 500; Readout Indication Minimum [ltr]** : 0.02; Readout Indication Maximum [ltr] : 99,999,999; Measuring Drum Volume [ltr] : 5.0; Pressure Loss Minimum [mbar] : 0.2
– Type TG 10, Flow Rate Minimum [ltr/h] : 20; Flow Rate Maximum [ltr/h] : 1,200; Flow Rate Standard [ltr/h]* : 1,000; Readout Indication Minimum [ltr]** : 0.1; Readout Indication Maximum [ltr] : 99,999,999; Measuring Drum Volume [ltr] : 10.0; Pressure Loss Minimum [mbar] : 0.1
– Type TG 20, Flow Rate Minimum [ltr/h] : 40; Flow Rate Maximum [ltr/h] : 4,000; Flow Rate Standard [ltr/h]* : 3,200; Readout Indication Minimum [ltr]** : 0.2; Readout Indication Maximum [ltr] : 999,999,990; Measuring Drum Volume [ltr] : 20.0; Pressure Loss Minimum [mbar] : 0.1
– Type TG 25, Flow Rate Minimum [ltr/h] : 50; Flow Rate Maximum [ltr/h] : 7,000; Flow Rate Standard [ltr/h]* : 5,000; Readout Indication Minimum [ltr]** : 0.1; Readout Indication Maximum [ltr] : 999,999,990; Measuring Drum Volume [ltr] : 25; Pressure Loss Minimum [mbar] : 0.1
– Type TG 50, Flow Rate Minimum [ltr/h] : 100; Flow Rate Maximum [ltr/h] : 18,000; Flow Rate Standard [ltr/h]* : 10,000; Readout Indication Minimum [ltr]** : 0.5; Readout Indication Maximum [ltr] : 999,999,990; Measuring Drum Volume [ltr] : 50.0; Pressure Loss Minimum [mbar] : 0.1

*At standard flow and 20°C (68°F) the measurement error (±0.2%) is determined
**Minimum dial division

The maximum gas inlet overpressure is dependent on the casing material: With plastic casings: 50 to 500 mbar / With SS casings: 0.5 to 35 bar
At standard flow and 20°C (68°F) the measurement error (±0.2%) is determined.

Deskripsi

Jual Gas Meter/Gas Purging TG-Series (Wet-Test) Ritter




Jual Alat Laboratorium Umum