LOCATION

MGK Kemayoran LT.GF Blok C.1 No.5

FLUKE 1746-30-INTL POWER QUALITY LOGGER W/60 CM 3,000A IFLEX

  • Functions: Voltage, current, power, power factor, frequency; Energy forward/reverse; Peak Demand; THD; Voltage and current harmonics (to 50th); Flicker; Unbalance
  • Rapid voltage change events; Interharmonics (to 50th); Dips, swells, interruption and transient events tables; Mains signaling; Inrush current
  • Recording: Trend

Deskripsi

Accuracy
VoltageRange: 1000 V
Maximum resolution: 0.1 V
Intrinsic accuracy at reference conditions (% of reading +% of range): ±0.1 % of nominal voltage
i17xx-flex 3000IP 24 3000 ARange: 300, 3000 A
Maximum resolution: 0.01 A (min. 3.0 A)3, 0.1 A
Intrinsic accuracy at reference conditions (% of reading +% of range): ±(1% + 0.03%)
VoltageRange: 42.5 to 69 Hz
Maximum resolution: 0.01 Hz
Intrinsic accuracy at reference conditions (% of reading +% of range): ±(0.1%)2
Auxiliary InputRange: ±10 V DC
Maximum resolution: 0.1 mV
Intrinsic accuracy at reference conditions (% of reading +% of range): ±(0.2% + 0.02%)
Voltage Min/MaxRange: 1000 V
Maximum resolution: 0.1 V
Intrinsic accuracy at reference conditions (% of reading +% of range): ±0.2 % of nominal input voltage
Current Min/MaxRange: Defined by accessory
Maximum resolution: Defined by accessory
Intrinsic accuracy at reference conditions (% of reading +% of range): ±(5% + 0.2%)
THD on VoltageRange: 1000%
Maximum resolution: 0.10%
Intrinsic accuracy at reference conditions (% of reading +% of range): ± 2.5%
THD on CurrentRange: 1000%
Maximum resolution: 0.10%
Intrinsic accuracy at reference conditions (% of reading +% of range): ± 2.5%
Voltage Harmonics 2nd to 50thRange: 1000 V
Maximum resolution: 0.1 V
Intrinsic accuracy at reference conditions (% of reading +% of range): ≥1 V: ±5% of reading, <1 V: ±0.05 V
Current Harmonics 2nd to 50thRange: Defined by accessory
Maximum resolution: Defined by accessory
Intrinsic accuracy at reference conditions (% of reading +% of range): ≥3% of current range: ±5% of reading, <3% of current range: ±0.15% of range
Flicker PLT, PSTRange: 0 to 20
Maximum resolution: 0.01
Intrinsic accuracy at reference conditions (% of reading +% of range): 5%
Electrical Specifications
Voltage Range100 to 500 V using safety plug input when powering from the measurement circuit
100 to 240 V MA-C8 and using standard power cord (IEC 60320 C7)
Power ConsumptionMaximum 50 VA (max. 15 VA when powered using MA-C8 adapter)
Efficiency≥68.2% (in accordance with energy efficiency regulations)
Maximum No-Load Consumption<0.3 W only when powered using IEC 60320 input
Mains Power Frequency50/60 Hz ±15%
BatteryLi-ion 3.7 V, 9.25 Wh, customer-replaceable
On-Battery RuntimeTypically 4 hours
Charging Time<6 hours
Data Acquisition
Resolution16-bit synchronous sampling
Sampling Frequency10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input Signal Frequency50/60 Hz (42.5 to 69 Hz)
Circuit Types1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ
delta open leg, currents only (load studies)
Data StorageInternal flash memory (not user replaceable)
Memory SizeTypical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events
Basic Interval
Measured ParametersVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging IntervalUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging Time Min/Max ValuesVoltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms)
Demand Interval (Energy Meter Mode)
Measured ParametersEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy
IntervalUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Power Quality Measurements
Measured ParameterVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation
Averaging Interval10 min for all parameters
2 hrs (long term Flicker PLT)
150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT)
Individual Harmonics2nd to 50th harmonic
Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only
Interharmonics1st to the 50th interharmonic
Total Harmonic DistortionCalculated on 50 voltage harmonics
EventsVoltage: dips, swells, interruptions, current: inrush current
Triggered RecordingsRMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30)
Waveform of voltage and current up to 200 ms, 10/12 cycles
Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120 s
InrushRMS profile based on ½ cycle RMS steady state triggering
FlickerIn accordance with IEC 61000-4-15 and IEEE 1453
Mains SignalingTwo user defined frequencies up to 3 kHz
PQ HealthSummarizes power quality measurements in one table. Detailed data available for each parameter
EN 50160Compliance with standard
Programmable PQ LimitsEnables user defined limits for local standards compliance
Standards Compliance
HarmonicsIEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics)
Power QualityIEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)
PowerIEEE 1459
Power Quality ComplianceEN 50160
SafetyGeneral: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 1000 V
Power Supply: Overvoltage Category IV, Pollution Degree 2
Li-ion Battery: IEC 62133
Interfaces
USB-AFile transfer via USB flash drive, firmware updates, max. supply current: 120 mA
Wi-FiFile transfer and remote control via direct connection or Wi-Fi infrastructure
BluetoothRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi/BLE adapter, check for availability)
USB-MiniData download device to PC
Voltage Inputs
Number of Inputs4 (3 phases referenced to neutral)
Maximum Input Voltage1000 Vrms, CF 1.7
Input impedance10 MΩ
Bandwidth42.5 Hz to 3.5 kHz
Scaling1:1 and variable
Measurement Category1000 V CAT III/600 V CAT IV
Current Inputs
Number of Inputs4 (3 phases and neutral), mode selected automatically for attached sensor
Input VoltageClamp input: 500/50 mVrms; CF 2.8
Rogowski coil input: 150/15 mVrms at 50 Hz, 180/18 mVrms at 60 Hz
CF 4 all at nominal probe range
Range1 to 150 A/10 to 1500 A with thin flexible current probe i17XX-flex1500 IP 24
Bandwidth42.5 Hz to 3.5 kHz
Scaling1:1 and variable
Auxiliary Inputs
Number of Inputs2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously)
Input Range0 to ± 10 V DC, or 0 to ± 1000 V DC (with optional adapter), 1 reading/s
Scale FactorFormat: mx + b (gain and offset) user configurable
Displayed UnitsUser configurable (7 characters, for example, °C, psi, or m/s)
Wireless Bluetooth Connection
Number of Inputs2
Supported ModulesFluke Connect® 3000 series
Acquisition1 reading/s
Environmental Specifications
Operating Temperature-13 to 122°F (-25 to 50°C)
Storage TemperatureWithout battery: -13 to 140°F (-25 to 60°C)
With battery: −4 to 122°F (-20 to 50°C)
Operating HumidityIEC 60721-3-3: 3K6:
-13 to 86°F (-25 to 30°C): ≤100%
104°F (40°C): 55%
122°F (50°C): 35%
Operating Altitude6561.7′ (2000 m) up to 13,123.4′ (4000 m) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV
Storage Altitude39,370.1′ (12,000 m)
EnclosureIEC 60529: IP50
IEC 60529: IP65 with IP65 rated voltage connector
VibrationIEC 60721-3-3 /3M2
Electromagnetic Compatibility (EMC)EN 61326-1: Industrial CISPR 11: Group 1, Class A
IEC 61000-6-5 Power station environment
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
General Specifications
Dimensions9.1 x 7.1 x 2.1″ (23 x 18 x 5.4 cm)
Weight2.2 lbs (1 kg)
Tamper ProtectionAccept securing cables (max. Φ 6mm)
Buka Whatsapp
1
PT Gowin Cakra Globalindo
Halo! Ada yang bisa kami bantu kak?